Energy Performance Certificate

54 Burnside Way, B31 4JY

EPC Report

Energy rating

Current: 45 E | Potential: 48 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 48 E Potential: 48 E

Environmental impact (CO₂)

Current: 51 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 54 Potential: 54
Field Value
LMK KEY 2553-1007-3202-1832-0204
ADDRESS1 54 Burnside Way
ADDRESS2
ADDRESS3
POSTCODE B31 4JY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 48
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2022-02-25
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001097
COUNTY
LODGEMENT DATE 2022-03-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 392
ENERGY CONSUMPTION POTENTIAL 369
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 750
HEATING COST POTENTIAL 664
HOT WATER COST CURRENT 623
HOT WATER COST POTENTIAL 623
TOTAL FLOOR AREA 58
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 54 Burnside Way
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Northfield
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2022-03-01 09:38:01
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100070313310
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display
Nation ew