Energy Performance Certificate

32, Croft Close, CH43 9QN

EPC Report

Energy rating

Current: 8 G | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 8 G Current: 8 G 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 16 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 74 Potential: 74
Field Value
LMK KEY 2538-3085-6202-9117-6900
ADDRESS1 32, Croft Close
ADDRESS2
ADDRESS3
POSTCODE CH43 9QN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 8
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-02-27
LOCAL AUTHORITY E08000015
CONSTITUENCY E14001091
COUNTY
LODGEMENT DATE 2013-02-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 778
ENERGY CONSUMPTION POTENTIAL 173
CO2 EMISSIONS CURRENT 9.7
CO2 EMISS CURR PER FLOOR AREA 138
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 1626
HEATING COST POTENTIAL 312
HOT WATER COST CURRENT 563
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 71
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric, Electric storage heaters
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32, Croft Close
LOCAL AUTHORITY LABEL Wirral
CONSTITUENCY LABEL Birkenhead
POSTTOWN PRENTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-02-27 14:54:38
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 42029095
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display