Energy Performance Certificate

4 Caves Close, Terrington St. Clement, PE34 4NQ

EPC Report

Energy rating

Current: 84 B | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 86 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 92 Potential: 92
Field Value
LMK KEY 2534-2161-1127-8717-5148
ADDRESS1 4 Caves Close
ADDRESS2 Terrington St. Clement
ADDRESS3
POSTCODE PE34 4NQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE Bungalow
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-07-09
LOCAL AUTHORITY E07000146
CONSTITUENCY E14001405
COUNTY
LODGEMENT DATE 2024-07-10
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 88
ENERGY CONSUMPTION POTENTIAL 48
CO2 EMISSIONS CURRENT 1
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 137
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 524
HEATING COST POTENTIAL 474
HOT WATER COST CURRENT 420
HOT WATER COST POTENTIAL 278
TOTAL FLOOR AREA 68
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 43
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 43% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 25
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Caves Close, Terrington St. Clement
LOCAL AUTHORITY LABEL King's Lynn and West Norfolk
CONSTITUENCY LABEL North West Norfolk
POSTTOWN KING'S LYNN
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-07-10 18:53:02
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100090969447
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display
Nation ew