Energy Performance Certificate

Flat 5, 67 Norbury Crescent, SW16 4JT

EPC Report

Energy rating

Current: 82 B | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 86 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 87 Potential: 87
Field Value
LMK KEY 2528-3075-7316-3365-9970
ADDRESS1 Flat 5
ADDRESS2 67 Norbury Crescent
ADDRESS3
POSTCODE SW16 4JT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2015-06-22
LOCAL AUTHORITY E09000008
CONSTITUENCY E14001527
COUNTY
LODGEMENT DATE 2015-06-22
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 93
ENERGY CONSUMPTION POTENTIAL 88
CO2 EMISSIONS CURRENT 0.8
CO2 EMISS CURR PER FLOOR AREA 16
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 187
HEATING COST POTENTIAL 189
HOT WATER COST CURRENT 54
HOT WATER COST POTENTIAL 54
TOTAL FLOOR AREA 52
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100.0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 53
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 53% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 5, 67 Norbury Crescent
LOCAL AUTHORITY LABEL Croydon
CONSTITUENCY LABEL Streatham and Croydon North
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-06-22 14:40:05
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10090926286
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew