Energy Performance Certificate

29 Compass Crescent, Old Whittington, S41 9LX

EPC Report

Energy rating

Current: 56 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 20 | Potential: 104
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 104 Potential: 104
Field Value
LMK KEY 2524-3045-1209-5885-9204
ADDRESS1 29 Compass Crescent
ADDRESS2 Old Whittington
ADDRESS3
POSTCODE S41 9LX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-01-22
LOCAL AUTHORITY E07000034
CONSTITUENCY E14001391
COUNTY
LODGEMENT DATE 2025-01-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 20
ENVIRONMENT IMPACT POTENTIAL 104
ENERGY CONSUMPTION CURRENT 330
ENERGY CONSUMPTION POTENTIAL 148
CO2 EMISSIONS CURRENT 9.3
CO2 EMISS CURR PER FLOOR AREA 126
CO2 EMISSIONS POTENTIAL -0.4
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 1270
HEATING COST POTENTIAL 1168
HOT WATER COST CURRENT 411
HOT WATER COST POTENTIAL 162
TOTAL FLOOR AREA 74
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, anthracite
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL anthracite
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29 Compass Crescent, Old Whittington
LOCAL AUTHORITY LABEL Chesterfield
CONSTITUENCY LABEL North East Derbyshire
POSTTOWN CHESTERFIELD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-01-22 20:48:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 74027191
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000004
Address display
Nation ew