Energy Performance Certificate

Flat 7, 7 Campbell Road, BH1 4EP

EPC Report

Energy rating

Current: 66 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 91 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 92 Potential: 92
Field Value
LMK KEY 2519-1095-2002-0798-4502
ADDRESS1 Flat 7
ADDRESS2 7 Campbell Road
ADDRESS3
POSTCODE BH1 4EP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2025-08-15
LOCAL AUTHORITY E06000058
CONSTITUENCY E14001115
COUNTY
LODGEMENT DATE 2025-08-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 213
ENERGY CONSUMPTION POTENTIAL 211
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 19
LIGHTING COST POTENTIAL 21
HEATING COST CURRENT 452
HEATING COST POTENTIAL 308
HOT WATER COST CURRENT 274
HOT WATER COST POTENTIAL 216
TOTAL FLOOR AREA 19
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 1.1
FLOOR HEIGHT 2.99
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 7, 7 Campbell Road
LOCAL AUTHORITY LABEL Bournemouth, Christchurch and Poole
CONSTITUENCY LABEL Bournemouth East
POSTTOWN BOURNEMOUTH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-08-15 13:32:42
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100040721259
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew