Energy Performance Certificate

Flat 1, 18 Winmarleigh Street, WA1 1NB

EPC Report

Energy rating

Current: 49 E | Potential: 49 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 49 E Potential: 49 E

Environmental impact (CO₂)

Current: 54 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 54 Potential: 54
Field Value
LMK KEY 2518-6944-7359-6318-7910
ADDRESS1 Flat 1
ADDRESS2 18 Winmarleigh Street
ADDRESS3
POSTCODE WA1 1NB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 49
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2018-11-29
LOCAL AUTHORITY E06000007
CONSTITUENCY E14001565
COUNTY
LODGEMENT DATE 2018-12-04
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 441
ENERGY CONSUMPTION POTENTIAL 441
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 75
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 27
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 601
HEATING COST POTENTIAL 601
HOT WATER COST CURRENT 148
HOT WATER COST POTENTIAL 148
TOTAL FLOOR AREA 33
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Average thermal transmittance 0.30 W/m²K
FLOOR ENERGY EFF Good
FLOOR ENV EFF Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.95 W/m²K
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.3 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 1, 18 Winmarleigh Street
LOCAL AUTHORITY LABEL Warrington
CONSTITUENCY LABEL Warrington South
POSTTOWN WARRINGTON
CONSTRUCTION AGE BAND 2018
LODGEMENT DATETIME 2018-12-04 13:27:32
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10092995831
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display
Nation ew