Energy Performance Certificate

1, Church View, DN18 6LD

EPC Report

Energy rating

Current: 78 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 73 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 75 Potential: 75
Field Value
LMK KEY 2498-4071-6257-4657-9904
ADDRESS1 1, Church View
ADDRESS2
ADDRESS3
POSTCODE DN18 6LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2013-03-21
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001128
COUNTY
LODGEMENT DATE 2013-03-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 228
ENERGY CONSUMPTION POTENTIAL 209
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 34
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 148
HEATING COST POTENTIAL 126
HOT WATER COST CURRENT 173
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 46
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 2.6
FLOOR HEIGHT 2.06
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Church View
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Brigg and Immingham
POSTTOWN BARTON-UPON-HUMBER
CONSTRUCTION AGE BAND England and Wales: 2007 onwards
LODGEMENT DATETIME 2013-03-21 13:52:20
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200000884691
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew