Energy Performance Certificate

46 The Springs, Middleham, DL8 4RB

EPC Report

Energy rating

Current: 57 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 57 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 64 Potential: 64
Field Value
LMK KEY 2480-3015-0205-9696-8200
ADDRESS1 46 The Springs
ADDRESS2 Middleham
ADDRESS3
POSTCODE DL8 4RB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2026-05-28
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001444
COUNTY
LODGEMENT DATE 2026-05-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 303
ENERGY CONSUMPTION POTENTIAL 248
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 874
HEATING COST POTENTIAL 803
HOT WATER COST CURRENT 298
HOT WATER COST POTENTIAL 263
TOTAL FLOOR AREA 57
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 46 The Springs, Middleham
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Richmond and Northallerton
POSTTOWN LEYBURN
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2026-05-28 18:23:38
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100050439160
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000003
Address display
Nation ew