Energy Performance Certificate

Brackendell, Palesgate Lane, TN6 3HF

EPC Report

Energy rating

Current: 17 G | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 11 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 Current: 11 58 Potential: 58
Field Value
LMK KEY 2458-6062-7232-1171-1904
ADDRESS1 Brackendell
ADDRESS2 Palesgate Lane
ADDRESS3
POSTCODE TN6 3HF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-02-25
LOCAL AUTHORITY E07000065
CONSTITUENCY E14001533
COUNTY
LODGEMENT DATE 2019-02-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 11
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 564
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT 12.9
CO2 EMISS CURR PER FLOOR AREA 135
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1976
HEATING COST POTENTIAL 1017
HOT WATER COST CURRENT 360
HOT WATER COST POTENTIAL 169
TOTAL FLOOR AREA 96
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 50
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Brackendell, Palesgate Lane
LOCAL AUTHORITY LABEL Wealden
CONSTITUENCY LABEL Sussex Weald
POSTTOWN CROWBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2019-02-27 07:35:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 100060109495
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew