Energy Performance Certificate

5, Cormorant Close, NE63 0DP

EPC Report

Energy rating

Current: 67 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 63 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 84 Potential: 84
Field Value
LMK KEY 2458-1914-7299-4205-8990
ADDRESS1 5, Cormorant Close
ADDRESS2
ADDRESS3
POSTCODE NE63 0DP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-11-25
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001107
COUNTY
LODGEMENT DATE 2015-11-25
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 230
ENERGY CONSUMPTION POTENTIAL 99
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 111
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 750
HEATING COST POTENTIAL 541
HOT WATER COST CURRENT 127
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 106
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Cormorant Close
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL Blyth and Ashington
POSTTOWN ASHINGTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2015-11-25 15:41:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100110651565
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000001
Address display
Nation ew