Energy Performance Certificate

2 WOODGRANGE AVENUE, EALING, W5 3NY

EPC Report

Energy rating

Current: 61 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 53 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 75 Potential: 75
Field Value
LMK KEY 2457-0001-0202-9409-2200
ADDRESS1 2 WOODGRANGE AVENUE
ADDRESS2 EALING
ADDRESS3
POSTCODE W5 3NY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-02-25
LOCAL AUTHORITY E09000009
CONSTITUENCY E14001207
COUNTY
LODGEMENT DATE 2021-02-25
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 253
ENERGY CONSUMPTION POTENTIAL 134
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 758
HEATING COST POTENTIAL 384
HOT WATER COST CURRENT 95
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 99
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.83
FLOOR HEIGHT 3.02
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 WOODGRANGE AVENUE, EALING
LOCAL AUTHORITY LABEL Ealing
CONSTITUENCY LABEL Ealing Central and Acton
POSTTOWN EALING
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-02-25 15:42:07
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 12090770
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew