Energy Performance Certificate

8 Tyne Road, Walney, LA14 3NA

EPC Report

Energy rating

Current: 64 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 67 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 77 Potential: 77
Field Value
LMK KEY 2449-3061-7204-3266-6204
ADDRESS1 8 Tyne Road
ADDRESS2 Walney
ADDRESS3
POSTCODE LA14 3NA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2026-04-24
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001076
COUNTY
LODGEMENT DATE 2026-04-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 232
ENERGY CONSUMPTION POTENTIAL 153
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 966
HEATING COST POTENTIAL 698
HOT WATER COST CURRENT 273
HOT WATER COST POTENTIAL 273
TOTAL FLOOR AREA 68
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 58
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 125 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.51
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8 Tyne Road, Walney
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Barrow and Furness
POSTTOWN BARROW-IN-FURNESS
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2026-04-24 19:41:35
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 36000514
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000002
Address display
Nation ew