Energy Performance Certificate

31 Fairfax House, Barkerend Road, BD1 4AR

EPC Report

Energy rating

Current: 65 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 60 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 62 Potential: 62
Field Value
LMK KEY 2435-0024-7500-0732-0226
ADDRESS1 31 Fairfax House
ADDRESS2 Barkerend Road
ADDRESS3
POSTCODE BD1 4AR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2025-04-22
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001120
COUNTY
LODGEMENT DATE 2025-05-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 292
ENERGY CONSUMPTION POTENTIAL 284
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 51
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 128
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 713
HEATING COST POTENTIAL 722
HOT WATER COST CURRENT 165
HOT WATER COST POTENTIAL 165
TOTAL FLOOR AREA 64
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, no thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, no thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31 Fairfax House, Barkerend Road
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Bradford West
POSTTOWN BRADFORD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2025-05-07 13:44:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100051134463
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000003
Address display