Energy Performance Certificate

73, Burnside, CB1 3PA

EPC Report

Energy rating

Current: 23 F | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 9 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 9 Current: 9 80 Potential: 80
Field Value
LMK KEY 2428-9085-7204-2724-4950
ADDRESS1 73, Burnside
ADDRESS2
ADDRESS3
POSTCODE CB1 3PA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-04-22
LOCAL AUTHORITY E07000008
CONSTITUENCY E14001149
COUNTY
LODGEMENT DATE 2014-04-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 9
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 957
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 171
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 1369
HEATING COST POTENTIAL 513
HOT WATER COST CURRENT 179
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 62
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 73, Burnside
LOCAL AUTHORITY LABEL Cambridge
CONSTITUENCY LABEL Cambridge
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-04-22 19:50:33
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 200004184300
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew