Energy Performance Certificate

36, Highfield, Clyst Road, EX3 0DA

EPC Report

Energy rating

Current: 35 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 22 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 62 Potential: 62
Field Value
LMK KEY 2418-4935-7232-4915-4964
ADDRESS1 36, Highfield
ADDRESS2 Clyst Road
ADDRESS3
POSTCODE EX3 0DA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-12-29
LOCAL AUTHORITY E07000041
CONSTITUENCY E14001232
COUNTY
LODGEMENT DATE 2015-12-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 611
ENERGY CONSUMPTION POTENTIAL 205
CO2 EMISSIONS CURRENT 7.8
CO2 EMISS CURR PER FLOOR AREA 103
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1047
HEATING COST POTENTIAL 451
HOT WATER COST CURRENT 278
HOT WATER COST POTENTIAL 89
TOTAL FLOOR AREA 76
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36, Highfield, Clyst Road
LOCAL AUTHORITY LABEL Exeter
CONSTITUENCY LABEL Exmouth and Exeter East
POSTTOWN EXETER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-12-29 14:14:21
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100040208347
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew