Energy Performance Certificate

27, The Crescent, Maghull, L31 7BL

EPC Report

Energy rating

Current: 17 G | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 6 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 6 Current: 6 83 Potential: 83
Field Value
LMK KEY 2408-2974-7290-3695-9974
ADDRESS1 27, The Crescent
ADDRESS2 Maghull
ADDRESS3
POSTCODE L31 7BL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-10-20
LOCAL AUTHORITY E08000014
CONSTITUENCY E14001463
COUNTY
LODGEMENT DATE 2015-10-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 6
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 1046
ENERGY CONSUMPTION POTENTIAL 97
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 177
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 1603
HEATING COST POTENTIAL 414
HOT WATER COST CURRENT 260
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 63
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 83
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27, The Crescent, Maghull
LOCAL AUTHORITY LABEL Sefton
CONSTITUENCY LABEL Sefton Central
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-10-20 13:16:32
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 41094654
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew