Energy Performance Certificate

3 HUNSLET STREET, BURNLEY, BB11 3DH

EPC Report

Energy rating

Current: 72 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 72 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 90 Potential: 90
Field Value
LMK KEY 2376-3003-8202-3789-9204
ADDRESS1 3 HUNSLET STREET
ADDRESS2 BURNLEY
ADDRESS3
POSTCODE BB11 3DH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-02-23
LOCAL AUTHORITY E07000117
CONSTITUENCY E14001142
COUNTY
LODGEMENT DATE 2021-02-23
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 210
ENERGY CONSUMPTION POTENTIAL 81
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 363
HEATING COST POTENTIAL 332
HOT WATER COST CURRENT 91
HOT WATER COST POTENTIAL 62
TOTAL FLOOR AREA 61
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.74
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 HUNSLET STREET, BURNLEY
LOCAL AUTHORITY LABEL Burnley
CONSTITUENCY LABEL Burnley
POSTTOWN BURNLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-02-23 13:22:19
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100010343790
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000002
Address display
Nation ew