Energy Performance Certificate

20, Ros Lyn, Carbis Bay, TR26 2QE

EPC Report

Energy rating

Current: 35 F | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 16 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 61 Potential: 61
Field Value
LMK KEY 2358-7915-7270-4686-0964
ADDRESS1 20, Ros Lyn
ADDRESS2 Carbis Bay
ADDRESS3
POSTCODE TR26 2QE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2016-10-25
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001511
COUNTY
LODGEMENT DATE 2016-10-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 735
ENERGY CONSUMPTION POTENTIAL 225
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 129
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 1021
HEATING COST POTENTIAL 425
HOT WATER COST CURRENT 203
HOT WATER COST POTENTIAL 85
TOTAL FLOOR AREA 65
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 14
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20, Ros Lyn, Carbis Bay
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Ives
POSTTOWN ST. IVES
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-10-25 15:13:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100040120193
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000009
Address display
Nation ew