Energy Performance Certificate

2, North View, Ludworth, DH6 1NF

EPC Report

Energy rating

Current: 18 G | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 7 | Potential: 44
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 7 Current: 7 44 Potential: 44
Field Value
LMK KEY 2338-8067-7213-3775-8964
ADDRESS1 2, North View
ADDRESS2 Ludworth
ADDRESS3
POSTCODE DH6 1NF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-07-27
LOCAL AUTHORITY E06000047
CONSTITUENCY E14001211
COUNTY
LODGEMENT DATE 2015-07-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 7
ENVIRONMENT IMPACT POTENTIAL 44
ENERGY CONSUMPTION CURRENT 971
ENERGY CONSUMPTION POTENTIAL 403
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 164
CO2 EMISSIONS POTENTIAL 6.8
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 2334
HEATING COST POTENTIAL 1040
HOT WATER COST CURRENT 392
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 99
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, North View, Ludworth
LOCAL AUTHORITY LABEL County Durham
CONSTITUENCY LABEL Easington
POSTTOWN DURHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-07-28 07:43:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100110422084
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000001
Address display
Nation ew