Energy Performance Certificate

22, School Lane, Colton, LS15 9AL

EPC Report

Energy rating

Current: 54 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 49 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 82 Potential: 82
Field Value
LMK KEY 2338-7904-7239-1067-7940
ADDRESS1 22, School Lane
ADDRESS2 Colton
ADDRESS3
POSTCODE LS15 9AL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-11-27
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001320
COUNTY
LODGEMENT DATE 2013-11-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 298
ENERGY CONSUMPTION POTENTIAL 104
CO2 EMISSIONS CURRENT 5.3
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 905
HEATING COST POTENTIAL 541
HOT WATER COST CURRENT 129
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 5
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 5% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, School Lane, Colton
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds East
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2013-11-28 21:48:37
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 72245701
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew