Energy Performance Certificate

6, Catherine Close, NG6 8JP

EPC Report

Energy rating

Current: 59 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 57 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 75 Potential: 75
Field Value
LMK KEY 2338-7056-6237-9678-0970
ADDRESS1 6, Catherine Close
ADDRESS2
ADDRESS3
POSTCODE NG6 8JP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2018-03-27
LOCAL AUTHORITY E06000018
CONSTITUENCY E14001411
COUNTY
LODGEMENT DATE 2018-03-29
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 291
ENERGY CONSUMPTION POTENTIAL 166
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 51
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 694
HEATING COST POTENTIAL 626
HOT WATER COST CURRENT 98
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 73
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Catherine Close
LOCAL AUTHORITY LABEL Nottingham
CONSTITUENCY LABEL Nottingham North and Kimberley
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-03-29 12:30:20
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100031530282
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000004
Address display
Nation ew