Energy Performance Certificate

73 High Street, CB24 8SD

EPC Report

Energy rating

Current: 70 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 63 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 69 Potential: 69
Field Value
LMK KEY 2335-2933-8500-0682-2222
ADDRESS1 73 High Street
ADDRESS2
ADDRESS3
POSTCODE CB24 8SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-07-22
LOCAL AUTHORITY E07000012
CONSTITUENCY E14001224
COUNTY
LODGEMENT DATE 2025-07-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 177
ENERGY CONSUMPTION POTENTIAL 147
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 155
LIGHTING COST POTENTIAL 155
HEATING COST CURRENT 1583
HEATING COST POTENTIAL 1583
HOT WATER COST CURRENT 144
HOT WATER COST POTENTIAL 144
TOTAL FLOOR AREA 185
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.48 W/m²K
FLOOR ENERGY EFF Poor
FLOOR ENV EFF Poor
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 1.04 W/m²K
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.74 W/m²K
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 73 High Street
LOCAL AUTHORITY LABEL South Cambridgeshire
CONSTITUENCY LABEL Ely and East Cambridgeshire
POSTTOWN COTTENHAM
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2025-07-22 14:16:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 100091421362
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew