Energy Performance Certificate

15, Townsend Road, Needingworth, PE27 4SE

EPC Report

Energy rating

Current: 47 E | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 48 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 94 Potential: 94
Field Value
LMK KEY 2318-8909-7200-2294-4994
ADDRESS1 15, Townsend Road
ADDRESS2 Needingworth
ADDRESS3
POSTCODE PE27 4SE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-10-29
LOCAL AUTHORITY E07000011
CONSTITUENCY E14001298
COUNTY
LODGEMENT DATE 2014-10-29
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 361
ENERGY CONSUMPTION POTENTIAL 30
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 674
HEATING COST POTENTIAL 317
HOT WATER COST CURRENT 294
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 61
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 11
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 11% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 15, Townsend Road, Needingworth
LOCAL AUTHORITY LABEL Huntingdonshire
CONSTITUENCY LABEL Huntingdon
POSTTOWN ST. IVES
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2014-10-29 17:30:45
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100090122330
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew