Energy Performance Certificate

40, Leytonstone Drive, DE22 4GE

EPC Report

Energy rating

Current: 50 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 43 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 73 Potential: 73
Field Value
LMK KEY 2318-8060-7221-4376-5974
ADDRESS1 40, Leytonstone Drive
ADDRESS2
ADDRESS3
POSTCODE DE22 4GE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-09-29
LOCAL AUTHORITY E06000015
CONSTITUENCY E14001193
COUNTY
LODGEMENT DATE 2016-09-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 414
ENERGY CONSUMPTION POTENTIAL 181
CO2 EMISSIONS CURRENT 5.2
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 880
HEATING COST POTENTIAL 649
HOT WATER COST CURRENT 239
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 72
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 40, Leytonstone Drive
LOCAL AUTHORITY LABEL Derby
CONSTITUENCY LABEL Derby North
POSTTOWN DERBY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-09-29 11:16:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100030331442
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew