Energy Performance Certificate

Treetops, Long Thurlow, IP31 3JA

EPC Report

Energy rating

Current: 79 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 81 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 89 Potential: 89
Field Value
LMK KEY 2311-7292-0887-3157-7125
ADDRESS1 Treetops
ADDRESS2 Long Thurlow
ADDRESS3
POSTCODE IP31 3JA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-03-31
LOCAL AUTHORITY E07000203
CONSTITUENCY E14001569
COUNTY
LODGEMENT DATE 2022-04-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 100
ENERGY CONSUMPTION POTENTIAL 55
CO2 EMISSIONS CURRENT 3
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 106
HEATING COST CURRENT 588
HEATING COST POTENTIAL 588
HOT WATER COST CURRENT 378
HOT WATER COST POTENTIAL 244
TOTAL FLOOR AREA 179
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.47
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Treetops, Long Thurlow
LOCAL AUTHORITY LABEL Mid Suffolk
CONSTITUENCY LABEL Waveney Valley
POSTTOWN BURY ST. EDMUNDS
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2022-04-04 18:00:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10012172885
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew