Energy Performance Certificate

Apartment 14, Grosvenor Apartments, Sandylands Promenade, LA3 1GW

EPC Report

Energy rating

Current: 79 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 81 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 81 Potential: 81
Field Value
LMK KEY 2308-3035-3202-9124-0200
ADDRESS1 Apartment 14
ADDRESS2 Grosvenor Apartments
ADDRESS3 Sandylands Promenade
POSTCODE LA3 1GW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-02-20
LOCAL AUTHORITY E07000121
CONSTITUENCY E14001372
COUNTY
LODGEMENT DATE 2024-02-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 161
ENERGY CONSUMPTION POTENTIAL 161
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 93
HEATING COST CURRENT 168
HEATING COST POTENTIAL 91
HOT WATER COST CURRENT 562
HOT WATER COST POTENTIAL 267
TOTAL FLOOR AREA 50
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Apartment 14, Grosvenor Apartments, Sandylands Promenade
LOCAL AUTHORITY LABEL Lancaster
CONSTITUENCY LABEL Morecambe and Lunesdale
POSTTOWN MORECAMBE
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2024-02-20 17:31:31
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10009280572
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000002
Address display
Nation ew