Energy Performance Certificate
THE VICARAGE, 23 ST PAUL'S ROAD, THORNTON HEATH, CR7 8NB
Energy rating
Current: 69 C | Potential: 75 C
Environmental impact (CO₂)
Current: 67
| Potential: 72
| Field | Value |
|---|---|
| LMK KEY | 2302-3005-0204-4829-7204 |
| ADDRESS1 | THE VICARAGE |
| ADDRESS2 | 23 ST PAUL'S ROAD |
| ADDRESS3 | THORNTON HEATH |
| POSTCODE | CR7 8NB |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 69 |
| POTENTIAL ENERGY EFFICIENCY | 75 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2021-04-20 |
| LOCAL AUTHORITY | E09000008 |
| CONSTITUENCY | E14001527 |
| COUNTY | — |
| LODGEMENT DATE | 2021-05-03 |
| TRANSACTION TYPE | Stock condition survey |
| ENVIRONMENT IMPACT CURRENT | 67 |
| ENVIRONMENT IMPACT POTENTIAL | 72 |
| ENERGY CONSUMPTION CURRENT | 146 |
| ENERGY CONSUMPTION POTENTIAL | 117 |
| CO2 EMISSIONS CURRENT | 5.1 |
| CO2 EMISS CURR PER FLOOR AREA | 26 |
| CO2 EMISSIONS POTENTIAL | 4.1 |
| LIGHTING COST CURRENT | 117 |
| LIGHTING COST POTENTIAL | 117 |
| HEATING COST CURRENT | 1196 |
| HEATING COST POTENTIAL | 1196 |
| HOT WATER COST CURRENT | 73 |
| HOT WATER COST POTENTIAL | 73 |
| TOTAL FLOOR AREA | 198 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 7 |
| NUMBER HEATED ROOMS | 7 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system, plus solar |
| HOT WATER ENERGY EFF | Very Good |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | System built, as built, insulated (assumed) |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | Room heaters, dual fuel (mineral and wood) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated at rafters |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.4 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | Y |
| MECHANICAL VENTILATION | mechanical, supply and extract |
| ADDRESS | THE VICARAGE, 23 ST PAUL'S ROAD, THORNTON HEATH |
| LOCAL AUTHORITY LABEL | Croydon |
| CONSTITUENCY LABEL | Streatham and Croydon North |
| POSTTOWN | THORNTON HEATH |
| CONSTRUCTION AGE BAND | England and Wales: 2012 onwards |
| LODGEMENT DATETIME | 2021-05-03 08:50:42 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 15 |
| LOW ENERGY FIXED LIGHT COUNT | 15 |
| UPRN | 10090383735 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2021.csv |
| COUNTRY | England |
| REGION | E12000007 |
| Address display | — |
| Nation | ew |