Energy Performance Certificate

101 Painswick Road, GL50 2EX

EPC Report

Energy rating

Current: 58 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 48 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 71 Potential: 71
Field Value
LMK KEY 2301-7907-2322-7092-1273
ADDRESS1 101 Painswick Road
ADDRESS2
ADDRESS3
POSTCODE GL50 2EX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2023-02-10
LOCAL AUTHORITY E07000078
CONSTITUENCY E14001161
COUNTY
LODGEMENT DATE 2023-02-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 258
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 4.0
LIGHTING COST CURRENT 130
LIGHTING COST POTENTIAL 131
HEATING COST CURRENT 1237
HEATING COST POTENTIAL 841
HOT WATER COST CURRENT 137
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 167
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 50
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 101 Painswick Road
LOCAL AUTHORITY LABEL Cheltenham
CONSTITUENCY LABEL Cheltenham
POSTTOWN CHELTENHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2023-02-10 09:22:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 100120393722
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000009
Address display
Nation ew