Energy Performance Certificate

19 The Ridings, LU3 1BY

EPC Report

Energy rating

Current: 67 D | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 48 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 77 Potential: 77
Field Value
LMK KEY 2301-1008-9206-7219-0204
ADDRESS1 19 The Ridings
ADDRESS2
ADDRESS3
POSTCODE LU3 1BY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-06-20
LOCAL AUTHORITY E06000032
CONSTITUENCY E14001346
COUNTY
LODGEMENT DATE 2021-11-26
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 427
ENERGY CONSUMPTION POTENTIAL 173
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 500
HEATING COST POTENTIAL 348
HOT WATER COST CURRENT 175
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 51
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19 The Ridings
LOCAL AUTHORITY LABEL Luton
CONSTITUENCY LABEL Luton South and South Bedfordshire
POSTTOWN LUTON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2021-11-26 17:12:28
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100080179165
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew