Energy Performance Certificate

31, New Cross Road, SE14 5DS

EPC Report

Energy rating

Current: 58 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 49 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 72 Potential: 72
Field Value
LMK KEY 2298-9028-6283-9656-9964
ADDRESS1 31, New Cross Road
ADDRESS2
ADDRESS3
POSTCODE SE14 5DS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-07-21
LOCAL AUTHORITY E09000023
CONSTITUENCY E14001332
COUNTY
LODGEMENT DATE 2016-07-24
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 217
ENERGY CONSUMPTION POTENTIAL 105
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 91
LIGHTING COST POTENTIAL 91
HEATING COST CURRENT 1220
HEATING COST POTENTIAL 792
HOT WATER COST CURRENT 144
HOT WATER COST POTENTIAL 90
TOTAL FLOOR AREA 167
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 58
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 12 mm loft insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, New Cross Road
LOCAL AUTHORITY LABEL Lewisham
CONSTITUENCY LABEL Lewisham North
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-07-24 19:50:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 100021990648
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew