Energy Performance Certificate

50 Gressel Lane, B33 9SX

EPC Report

Energy rating

Current: 54 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 55 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 83 Potential: 83
Field Value
LMK KEY 2298-3025-0207-3787-3200
ADDRESS1 50 Gressel Lane
ADDRESS2
ADDRESS3
POSTCODE B33 9SX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2023-03-21
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001095
COUNTY
LODGEMENT DATE 2023-03-26
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 314
ENERGY CONSUMPTION POTENTIAL 109
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 169
LIGHTING COST POTENTIAL 109
HEATING COST CURRENT 1226
HEATING COST POTENTIAL 957
HOT WATER COST CURRENT 737
HOT WATER COST POTENTIAL 162
TOTAL FLOOR AREA 66
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 50 Gressel Lane
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Hodge Hill and Solihull North
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2023-03-26 10:03:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100070387381
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000005
Address display
Nation ew