Energy Performance Certificate

2 LEWIS TERRACE, MAIN ROAD, FFYNNONGROYW, CH8 9UE

EPC Report

Energy rating

Current: 58 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 56 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 78 Potential: 78
Field Value
LMK KEY 2289-3901-0209-5541-8900
ADDRESS1 2 LEWIS TERRACE
ADDRESS2 MAIN ROAD
ADDRESS3 FFYNNONGROYW
POSTCODE CH8 9UE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-11-28
LOCAL AUTHORITY W06000005
CONSTITUENCY W07000094
COUNTY
LODGEMENT DATE 2020-12-01
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 339
ENERGY CONSUMPTION POTENTIAL 164
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 47
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 731
HEATING COST POTENTIAL 599
HOT WATER COST CURRENT 44
HOT WATER COST POTENTIAL 28
TOTAL FLOOR AREA 55
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 50
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, flue gas heat recovery
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.811
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 LEWIS TERRACE, MAIN ROAD, FFYNNONGROYW
LOCAL AUTHORITY LABEL Flintshire
CONSTITUENCY LABEL Clwyd East
POSTTOWN FFYNNONGROYW
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-12-01 15:09:00
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10013702827
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew