Energy Performance Certificate

22, Waverley Drive, GU15 2DL

EPC Report

Energy rating

Current: 41 E | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 32 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 49 Potential: 49
Field Value
LMK KEY 2268-2071-7262-6031-0960
ADDRESS1 22, Waverley Drive
ADDRESS2
ADDRESS3
POSTCODE GU15 2DL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-02-26
LOCAL AUTHORITY E07000214
CONSTITUENCY E14001532
COUNTY
LODGEMENT DATE 2019-02-26
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 349
ENERGY CONSUMPTION POTENTIAL 224
CO2 EMISSIONS CURRENT 18
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 12
LIGHTING COST CURRENT 151
LIGHTING COST POTENTIAL 151
HEATING COST CURRENT 3235
HEATING COST POTENTIAL 2316
HOT WATER COST CURRENT 191
HOT WATER COST POTENTIAL 125
TOTAL FLOOR AREA 289
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 80
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 81
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly secondary glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 81% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.05
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Waverley Drive
LOCAL AUTHORITY LABEL Surrey Heath
CONSTITUENCY LABEL Surrey Heath
POSTTOWN CAMBERLEY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2019-02-26 15:38:23
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 100061558981
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew