Energy Performance Certificate

119, Pennygate, PE11 1NN

EPC Report

Energy rating

Current: 37 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 31 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 80 Potential: 80
Field Value
LMK KEY 2258-2013-7267-3145-5950
ADDRESS1 119, Pennygate
ADDRESS2
ADDRESS3
POSTCODE PE11 1NN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-03-25
LOCAL AUTHORITY E07000140
CONSTITUENCY E14001487
COUNTY
LODGEMENT DATE 2015-03-26
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 532
ENERGY CONSUMPTION POTENTIAL 121
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 94
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1158
HEATING COST POTENTIAL 520
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 74
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 67
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 22
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 22% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 119, Pennygate
LOCAL AUTHORITY LABEL South Holland
CONSTITUENCY LABEL South Holland and The Deepings
POSTTOWN SPALDING
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-03-26 15:53:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100030891204
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew