Energy Performance Certificate
38, The Goldings, GU21 3RF
Energy rating
Current: 64 D | Potential: 83 B
Environmental impact (CO₂)
Current: 62
| Potential: 82
| Field | Value |
|---|---|
| LMK KEY | 2248-2041-6237-9680-9290 |
| ADDRESS1 | 38, The Goldings |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | GU21 3RF |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 64 |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| PROPERTY TYPE | House |
| BUILT FORM | End-Terrace |
| INSPECTION DATE | 2020-03-24 |
| LOCAL AUTHORITY | E07000217 |
| CONSTITUENCY | E14001592 |
| COUNTY | — |
| LODGEMENT DATE | 2020-07-07 |
| TRANSACTION TYPE | ECO assessment |
| ENVIRONMENT IMPACT CURRENT | 62 |
| ENVIRONMENT IMPACT POTENTIAL | 82 |
| ENERGY CONSUMPTION CURRENT | 227 |
| ENERGY CONSUMPTION POTENTIAL | 91 |
| CO2 EMISSIONS CURRENT | 3.2 |
| CO2 EMISS CURR PER FLOOR AREA | 40 |
| CO2 EMISSIONS POTENTIAL | 1.3 |
| LIGHTING COST CURRENT | 129 |
| LIGHTING COST POTENTIAL | 65 |
| HEATING COST CURRENT | 557 |
| HEATING COST POTENTIAL | 463 |
| HOT WATER COST CURRENT | 130 |
| HOT WATER COST POTENTIAL | 79 |
| TOTAL FLOOR AREA | 80 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 4 |
| NUMBER HEATED ROOMS | 4 |
| LOW ENERGY LIGHTING | 0 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, filled cavity |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.6 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 38, The Goldings |
| LOCAL AUTHORITY LABEL | Woking |
| CONSTITUENCY LABEL | Woking |
| POSTTOWN | WOKING |
| CONSTRUCTION AGE BAND | England and Wales: 1991-1995 |
| LODGEMENT DATETIME | 2020-07-07 11:54:01 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| UPRN | 100061658712 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2020.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |