Energy Performance Certificate

2, Norman Close, Marks Tey, CO6 1HJ

EPC Report

Energy rating

Current: 63 D | Potential: 108 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 108 A Potential: 108 A

Environmental impact (CO₂)

Current: 59 | Potential: 104
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 104 Potential: 104
Field Value
LMK KEY 2228-9949-7250-3295-9990
ADDRESS1 2, Norman Close
ADDRESS2 Marks Tey
ADDRESS3
POSTCODE CO6 1HJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 108
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-10-22
LOCAL AUTHORITY E07000071
CONSTITUENCY E14001590
COUNTY
LODGEMENT DATE 2015-10-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 104
ENERGY CONSUMPTION CURRENT 260
ENERGY CONSUMPTION POTENTIAL -52
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL -0.6
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 607
HEATING COST POTENTIAL 433
HOT WATER COST CURRENT 139
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 79
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Norman Close, Marks Tey
LOCAL AUTHORITY LABEL Colchester
CONSTITUENCY LABEL Witham
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-10-22 09:40:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100090467931
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew