Energy Performance Certificate

96, Arbor Way, B37 7LD

EPC Report

Energy rating

Current: 69 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 70 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 87 Potential: 87
Field Value
LMK KEY 2228-4070-7264-0484-9934
ADDRESS1 96, Arbor Way
ADDRESS2
ADDRESS3
POSTCODE B37 7LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-04-22
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001358
COUNTY
LODGEMENT DATE 2014-04-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 179
ENERGY CONSUMPTION POTENTIAL 73
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 559
HEATING COST POTENTIAL 454
HOT WATER COST CURRENT 93
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 83
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 96, Arbor Way
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Meriden and Solihull East
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-04-22 18:07:19
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100070951323
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew