Energy Performance Certificate

114 Redwald Road, Rendlesham, IP12 2TF

EPC Report

Energy rating

Current: 39 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 36 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 47 Potential: 47
Field Value
LMK KEY 2221-0761-1751-5491-9141
ADDRESS1 114 Redwald Road
ADDRESS2 Rendlesham
ADDRESS3
POSTCODE IP12 2TF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-11-09
LOCAL AUTHORITY E07000244
CONSTITUENCY E14001530
COUNTY
LODGEMENT DATE 2021-11-18
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 413
ENERGY CONSUMPTION POTENTIAL 311
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 97
HEATING COST CURRENT 1723
HEATING COST POTENTIAL 1168
HOT WATER COST CURRENT 524
HOT WATER COST POTENTIAL 297
TOTAL FLOOR AREA 119
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, extract only
ADDRESS 114 Redwald Road, Rendlesham
LOCAL AUTHORITY LABEL East Suffolk
CONSTITUENCY LABEL Suffolk Coastal
POSTTOWN WOODBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-11-18 17:20:22
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100091147785
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display