Energy Performance Certificate

39, Cemetery Road, BB3 2LZ

EPC Report

Energy rating

Current: 65 D | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 65 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 91 Potential: 91
Field Value
LMK KEY 2218-0093-7235-3365-4924
ADDRESS1 39, Cemetery Road
ADDRESS2
ADDRESS3
POSTCODE BB3 2LZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-05-29
LOCAL AUTHORITY E06000008
CONSTITUENCY E14001450
COUNTY
LODGEMENT DATE 2015-06-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 293
ENERGY CONSUMPTION POTENTIAL 98
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 51
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 640
HEATING COST POTENTIAL 418
HOT WATER COST CURRENT 112
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 65
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.18
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 39, Cemetery Road
LOCAL AUTHORITY LABEL Blackburn with Darwen
CONSTITUENCY LABEL Rossendale and Darwen
POSTTOWN DARWEN
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-06-01 12:28:14
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 200004501767
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew