Energy Performance Certificate

49, Clappers Meadow, Alfold, GU6 8HJ

EPC Report

Energy rating

Current: 60 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 52 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 56 Potential: 56
Field Value
LMK KEY 2198-9959-7280-2194-1930
ADDRESS1 49, Clappers Meadow
ADDRESS2 Alfold
ADDRESS3
POSTCODE GU6 8HJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Maisonette
BUILT FORM Semi-Detached
INSPECTION DATE 2014-10-21
LOCAL AUTHORITY E07000216
CONSTITUENCY E14001249
COUNTY
LODGEMENT DATE 2014-10-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 331
ENERGY CONSUMPTION POTENTIAL 303
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 604
HEATING COST POTENTIAL 283
HOT WATER COST CURRENT 181
HOT WATER COST POTENTIAL 127
TOTAL FLOOR AREA 61
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 49, Clappers Meadow, Alfold
LOCAL AUTHORITY LABEL Waverley
CONSTITUENCY LABEL Godalming and Ash
POSTTOWN CRANLEIGH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-10-21 16:06:50
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100061594220
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew