Energy Performance Certificate

3 Roman Quay, SP6 1RL

EPC Report

Energy rating

Current: 45 E | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 84 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 Current: 84 88 Potential: 88
Field Value
LMK KEY 2190-4029-8188-6500-3612
ADDRESS1 3 Roman Quay
ADDRESS2
ADDRESS3
POSTCODE SP6 1RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2026-04-20
LOCAL AUTHORITY E07000091
CONSTITUENCY E14001374
COUNTY
LODGEMENT DATE 2026-04-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 84
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 223
ENERGY CONSUMPTION POTENTIAL 178
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 47
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 1557
HEATING COST POTENTIAL 798
HOT WATER COST CURRENT 306
HOT WATER COST POTENTIAL 332
TOTAL FLOOR AREA 50
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 64
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 85
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 Roman Quay
LOCAL AUTHORITY LABEL New Forest
CONSTITUENCY LABEL New Forest West
POSTTOWN FORDINGBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2026-04-20 17:46:05
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100061999868
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000008
Address display
Nation ew