Energy Performance Certificate

16 Herivan Close, Oulton, NR32 3HY

EPC Report

Energy rating

Current: 91 B | Potential: 101 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 B Current: 91 B 101 A Potential: 101 A

Environmental impact (CO₂)

Current: 62 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 83 Potential: 83
Field Value
LMK KEY 2188-9200-6021-6126-2483
ADDRESS1 16 Herivan Close
ADDRESS2 Oulton
ADDRESS3
POSTCODE NR32 3HY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 91
POTENTIAL ENERGY EFFICIENCY 101
PROPERTY TYPE Bungalow
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-01-28
LOCAL AUTHORITY E07000244
CONSTITUENCY E14001344
COUNTY
LODGEMENT DATE 2025-02-05
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 311
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 549
HEATING COST POTENTIAL 467
HOT WATER COST CURRENT 329
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 39
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16 Herivan Close, Oulton
LOCAL AUTHORITY LABEL East Suffolk
CONSTITUENCY LABEL Lowestoft
POSTTOWN LOWESTOFT
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2025-02-05 21:58:58
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10012974956
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew