Energy Performance Certificate

65, East Road, Longsight, M12 5QY

EPC Report

Energy rating

Current: 40 E | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 31 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 55 Potential: 55
Field Value
LMK KEY 2188-9023-7219-3306-4900
ADDRESS1 65, East Road
ADDRESS2 Longsight
ADDRESS3
POSTCODE M12 5QY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-01-28
LOCAL AUTHORITY E08000003
CONSTITUENCY E14001251
COUNTY
LODGEMENT DATE 2016-01-28
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 367
ENERGY CONSUMPTION POTENTIAL 201
CO2 EMISSIONS CURRENT 19
CO2 EMISS CURR PER FLOOR AREA 65
CO2 EMISSIONS POTENTIAL 10
LIGHTING COST CURRENT 200
LIGHTING COST POTENTIAL 110
HEATING COST CURRENT 3548
HEATING COST POTENTIAL 2114
HOT WATER COST CURRENT 134
HOT WATER COST POTENTIAL 120
TOTAL FLOOR AREA 285
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas, Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.06
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 65, East Road, Longsight
LOCAL AUTHORITY LABEL Manchester
CONSTITUENCY LABEL Gorton and Denton
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-01-28 23:48:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100011066540
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew