Energy Performance Certificate

31, Columbine Close, IP24 2YF

EPC Report

Energy rating

Current: 57 D | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 53 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 77 Potential: 77
Field Value
LMK KEY 2188-6941-7230-6371-4904
ADDRESS1 31, Columbine Close
ADDRESS2
ADDRESS3
POSTCODE IP24 2YF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2019-10-28
LOCAL AUTHORITY E07000143
CONSTITUENCY E14001497
COUNTY
LODGEMENT DATE 2019-10-28
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 434
ENERGY CONSUMPTION POTENTIAL 194
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 40
HEATING COST CURRENT 541
HEATING COST POTENTIAL 330
HOT WATER COST CURRENT 192
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 40
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Columbine Close
LOCAL AUTHORITY LABEL Breckland
CONSTITUENCY LABEL South West Norfolk
POSTTOWN THETFORD
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2019-10-28 20:17:51
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100091497672
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew