Energy Performance Certificate

7 Stanmore Avenue, TS4 3EQ

EPC Report

Energy rating

Current: 79 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 73 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 76 Potential: 76
Field Value
LMK KEY 2187-1121-1121-1186-1193
ADDRESS1 7 Stanmore Avenue
ADDRESS2
ADDRESS3
POSTCODE TS4 3EQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-04-14
LOCAL AUTHORITY E06000002
CONSTITUENCY E14001367
COUNTY
LODGEMENT DATE 2022-04-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 157
ENERGY CONSUMPTION POTENTIAL 139
CO2 EMISSIONS CURRENT 3
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 664
HEATING COST POTENTIAL 638
HOT WATER COST CURRENT 96
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 107
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7 Stanmore Avenue
LOCAL AUTHORITY LABEL Middlesbrough
CONSTITUENCY LABEL Middlesbrough and Thornaby East
POSTTOWN MIDDLESBROUGH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2022-04-28 16:46:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100110136715
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000001
Address display
Nation ew