Energy Performance Certificate

29 Low Habberley, DY11 5RA

EPC Report

Energy rating

Current: 89 B | Potential: 100 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 B Current: 89 B 100 A Potential: 100 A

Environmental impact (CO₂)

Current: 90 | Potential: 100
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 90 Current: 90 100 Potential: 100
Field Value
LMK KEY 2181-7169-1797-1481-2163
ADDRESS1 29 Low Habberley
ADDRESS2
ADDRESS3
POSTCODE DY11 5RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 89
POTENTIAL ENERGY EFFICIENCY 100
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-08-16
LOCAL AUTHORITY E07000239
CONSTITUENCY E14001601
COUNTY
LODGEMENT DATE 2024-08-25
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 90
ENVIRONMENT IMPACT POTENTIAL 100
ENERGY CONSUMPTION CURRENT 51
ENERGY CONSUMPTION POTENTIAL -11
CO2 EMISSIONS CURRENT 0.9
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL -0.2
LIGHTING COST CURRENT 122
LIGHTING COST POTENTIAL 122
HEATING COST CURRENT 1342
HEATING COST POTENTIAL 881
HOT WATER COST CURRENT 436
HOT WATER COST POTENTIAL 289
TOTAL FLOOR AREA 107
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 80
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29 Low Habberley
LOCAL AUTHORITY LABEL Wyre Forest
CONSTITUENCY LABEL Wyre Forest
POSTTOWN KIDDERMINSTER
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-08-25 15:53:37
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10003366514
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000005
Address display
Nation ew