Energy Performance Certificate

Flat 47, Southend House, 141 Footscray Road, SE9 2TA

EPC Report

Energy rating

Current: 71 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 56 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 63 Potential: 63
Field Value
LMK KEY 2180-7727-2040-6309-5225
ADDRESS1 Flat 47
ADDRESS2 Southend House
ADDRESS3 141 Footscray Road
POSTCODE SE9 2TA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2024-03-25
LOCAL AUTHORITY E09000011
CONSTITUENCY E14001223
COUNTY
LODGEMENT DATE 2024-03-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 311
ENERGY CONSUMPTION POTENTIAL 259
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 164
LIGHTING COST POTENTIAL 127
HEATING COST CURRENT 627
HEATING COST POTENTIAL 468
HOT WATER COST CURRENT 301
HOT WATER COST POTENTIAL 252
TOTAL FLOOR AREA 56
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 1.75
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 47, Southend House, 141 Footscray Road
LOCAL AUTHORITY LABEL Greenwich
CONSTITUENCY LABEL Eltham and Chislehurst
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2024-03-25 20:50:31
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100023282769
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew