Energy Performance Certificate

Cantium Lodge, Terrace Road, ME16 8HU

EPC Report

Energy rating

Current: 75 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 76 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 90 Potential: 90
Field Value
LMK KEY 2178-7079-7368-6161-2980
ADDRESS1 Cantium Lodge
ADDRESS2 Terrace Road
ADDRESS3
POSTCODE ME16 8HU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2019-08-23
LOCAL AUTHORITY E07000110
CONSTITUENCY E14001349
COUNTY
LODGEMENT DATE 2019-08-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 167
ENERGY CONSUMPTION POTENTIAL 46
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 300
HEATING COST POTENTIAL 300
HOT WATER COST CURRENT 71
HOT WATER COST POTENTIAL 44
TOTAL FLOOR AREA 56
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.36 W/m²K
FLOOR ENERGY EFF Average
FLOOR ENV EFF Average
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.30 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.16 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Cantium Lodge, Terrace Road
LOCAL AUTHORITY LABEL Maidstone
CONSTITUENCY LABEL Maidstone and Malling
POSTTOWN MAIDSTONE
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2019-08-23 09:03:42
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 200003668675
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew