Energy Performance Certificate

16, Deans Gate Close, SE23 2XX

EPC Report

Energy rating

Current: 69 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 67 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 80 Potential: 80
Field Value
LMK KEY 2178-3052-6258-4453-6984
ADDRESS1 16, Deans Gate Close
ADDRESS2
ADDRESS3
POSTCODE SE23 2XX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-08-23
LOCAL AUTHORITY E09000023
CONSTITUENCY E14001333
COUNTY
LODGEMENT DATE 2017-08-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 209
ENERGY CONSUMPTION POTENTIAL 126
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 253
HEATING COST POTENTIAL 223
HOT WATER COST CURRENT 284
HOT WATER COST POTENTIAL 135
TOTAL FLOOR AREA 70
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Deans Gate Close
LOCAL AUTHORITY LABEL Lewisham
CONSTITUENCY LABEL Lewisham West and East Dulwich
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2017-08-23 20:01:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100021951140
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew